Parameters
List of Parameters
1-182
© Siemens AG 2007 All Rights Reserved
SINAMICS G120 Control Units CU240S, Edition 05/2007
Description: Sets waiting time for change from open-loop to closed-loop control mode.
Note: Exceeds the output frequency (r66) the transition frequency to closed loop (P1755) the waiting time (P1759) will be
ignored.
Description: Enters gain of speed adaptation controller for sensorless vector control.
Description: Enters speed adaptation controller integral time.
Description: Displays proportional part of speed adaptation controller.
Description: Displays integral part of speed adaptation controller.
Description: Displays flux angle difference between motor model and current transformation before motor model is active.
p1759[0...2] T(wait) transit to closed-loop / T(wait) trans.->CL
Access level: 3 P-Group: Closed-loop control Data type: Unsigned16
Quick comm. NO Active: YES Data set: DDS
Can be changed: U, T
Min Max Factory setting
0 [ms] 2000 [ms] 0 [ms]
p1764[0...2] Kp of n-adaption (SLVC) / Kp n-adapt. (SLVC)
Access level: 3 P-Group: Closed-loop control Data type: Floating Point
Quick comm. NO Active: YES Data set: DDS
Can be changed: U, T
Min Max Factory setting
0.0 2.5 0.2
p1767[0...2] Tn of n-adaption (SLVC) / Tn n-adapt. (SLVC)
Access level: 4 P-Group: Closed-loop control Data type: Floating Point
Quick comm. NO Active: YES Data set: DDS
Can be changed: U, T
Min Max Factory setting
1.0 [ms] 200.0 [ms] 4.0 [ms]
r1770 CO: Prop. output of n-adaption / Prop outp n-ad
Access level: 3 P-Group: Closed-loop control Data type: Floating Point
Unit: [Hz] Data set: -
r1771 CO: Int. output of n-adaption / Int. outp n-ad
Access level: 3 P-Group: Closed-loop control Data type: Floating Point
Unit: [Hz] Data set: -
r1778 CO: Flux angle difference / Flux angle diff
Access level: 4 P-Group: Closed-loop control Data type: Floating Point
Unit: [°] Data set: -