EasyManua.ls Logo

Siemens Sinamics G120 Series - p2481[0...2] Gearbox ratio input; Gearbox ratio in; p2482[0...2] Gearbox ratio output; Gearbox ratio out; p2484[0...2] No. of shaft turns = 1 Unit; Position ref. unit

Siemens Sinamics G120 Series
418 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
List of Parameters
Parameters
1-253
© Siemens AG 2007 All Rights Reserved
SINAMICS G120 Control Units CU240S, Edition 05/2007
Description: P2481 and P2482 define the gear box ratio for the positioning ramp down functionality. P2481 sets the motor shaft
side (gear box input).
Description: P2481 and P2482 define the gear box ratio for the positioning ramp down functionality. P2482 sets the load side
(gear box output).
Description: Sets the number of rotations of the motor shaft required to represent 1 unit of user selected units.
The following equation determines the number of motor shaft revolutions to stop:
p2481[0...2] Gearbox ratio input / Gearbox ratio in
Access level: 3 P-Group: Closed-loop control Data type: Floating Point
Quick comm. NO Active: NO Data set: DDS
Can be changed: U, T
Min Max Factory setting
0.01 9999.99 1.00
n n
Motor Load
Load
i
i =
P2482
P2481
=
Motor revolutions
Load revolutions
Motor
Gear
p2482[0...2] Gearbox ratio output / Gearbox ratio out
Access level: 3 P-Group: Closed-loop control Data type: Floating Point
Quick comm. NO Active: NO Data set: DDS
Can be changed: U, T
Min Max Factory setting
0.01 9999.99 1.00
p2484[0...2] No. of shaft turns = 1 Unit / Position ref. unit
Access level: 3 P-Group: Closed-loop control Data type: Floating Point
Quick comm. NO Active: NO Data set: DDS
Can be changed: U, T
Min Max Factory setting
0.01 9999.99 1.00
==
s
U
P2484
Load
Mo
t
o
r
Pulley radius r
No. of revolutions
1 [unit]
U
Distance s
2482P
2481P
2484P2488P =
Revolutions
Motor

Table of Contents