Parameters
List of Parameters
1-20
© Siemens AG 2007 All Rights Reserved
SINAMICS G120 Control Units CU240S, Edition 05/2007
Description: Displays status of operator panel commands.
The settings below are used as the "source" codes for keypad control when connecting to BICO input parameters.
Note: When BICO technology is used to allocate functions to panel buttons, this parameter displays the actual status of
the relevant command.
Description: Displays actual frequency setpoint (input of ramp function generator). This value is available filtered (r0020) and
unfiltered (r1119).
Description: Displays actual inverter output frequency (r0024) excluding slip compensation, resonance damping and frequency
limitation.
Description: Displays calculated rotor speed based on r0021 (filtered output frequency [Hz] x 120 / number of poles). The value
is updated every 128 ms.
Note: This calculation makes no allowance for load-dependent slip.
Description: Displays actual filtered output frequency (slip compensation, resonance damping and frequency limitation are
included). See also r0021.
This value is available filtered (r0024) and unfiltered (r0066).
r0019.0...14 CO/BO: BOP control word / BOP CtrlWd
Access level: 3 P-Group: Commands Data type: Unsigned16
Unit: - Data set: -
Bit field: Bit Signal name 1 signal 0 signal FP
00 ON/OFF1 Yes No -
01 OFF2: Electrical stop No Yes -
08 JOG right Yes No -
11 Reverse (setpoint inversion) Yes No -
13 Motor potentiometer MOP up Yes No -
14 Motor potentiometer MOP down Yes No -
r0020 CO: Freq. setpoint before RFG / Setp before RFG
Access level: 3 P-Group: Closed-loop control Data type: Floating Point
Unit: [Hz] Data set: -
Motor
control
RFG
Skip
frequency
Inhibit
neg. freq.
setpoint
Reverse
Setpoint
source
r1079 r0020 r1170
P1110 P1091 P1080 P1082 P1120 P1135
. . .
IfI
r1078
JOG
r1114
r1119
r0021 CO: Act. filtered frequency / Act. filt. freq.
Access level: 2 P-Group: Closed-loop control Data type: Floating Point
Unit: [Hz] Data set: -
r0022 Act. filtered rotor speed / Act fil rotorspeed
Access level: 3 P-Group: Closed-loop control Data type: Floating Point
Unit: [RPM] Data set: -
r0024 CO: Act. filt. output frequency / Act. outp. freq
Access level: 3 P-Group: Closed-loop control Data type: Floating Point
Unit: [Hz] Data set: -