EasyManua.ls Logo

Siemens Sinamics G120 Series - p2185[0...2] Upper torque threshold 1; Upper trq. thresh1; p2186[0...2] Lower torque threshold 1; Lower trq. thresh1; p2187[0...2] Upper torque threshold 2; Upper trq. thresh2; p2188[0...2] Lower torque threshold 2; Lower trq. thresh2

Siemens Sinamics G120 Series
418 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameters
List of Parameters
1-234
© Siemens AG 2007 All Rights Reserved
SINAMICS G120 Control Units CU240S, Edition 05/2007
Description: Upper limit threshold value 1 for comparing actual torque.
Note: See P2182 (belt threshold frequency 1).
Description: Lower limit threshold value 1 for comparing actual torque.
Note: See P2182 (belt threshold frequency 1).
Description: Upper limit threshold value 2 for comparing actual torque.
Note: See P2182 (belt threshold frequency 1).
Description: Lower limit threshold value 2 for comparing actual torque.
Note: See P2182 (belt threshold frequency 1).
Description: Upper limit threshold value 3 for comparing actual torque.
Note: See P2182 (belt threshold frequency 1).
p2185[0...2] Upper torque threshold 1 / Upper trq. thresh1
Access level: 2 P-Group: Messages Data type: Floating Point
Quick comm. NO Active: YES Data set: DDS
Can be changed: U, T
Min Max Factory setting
0.0 [Nm] 99999.0 [Nm] 99999.0 [Nm]
p2186[0...2] Lower torque threshold 1 / Lower trq. thresh1
Access level: 2 P-Group: Messages Data type: Floating Point
Quick comm. NO Active: YES Data set: DDS
Can be changed: U, T
Min Max Factory setting
0.0 [Nm] 99999.0 [Nm] 0.0 [Nm]
p2187[0...2] Upper torque threshold 2 / Upper trq. thresh2
Access level: 2 P-Group: Messages Data type: Floating Point
Quick comm. NO Active: YES Data set: DDS
Can be changed: U, T
Min Max Factory setting
0.0 [Nm] 99999.0 [Nm] 99999.0 [Nm]
p2188[0...2] Lower torque threshold 2 / Lower trq. thresh2
Access level: 2 P-Group: Messages Data type: Floating Point
Quick comm. NO Active: YES Data set: DDS
Can be changed: U, T
Min Max Factory setting
0.0 [Nm] 99999.0 [Nm] 0.0 [Nm]
p2189[0...2] Upper torque threshold 3 / Upper trq. thresh3
Access level: 2 P-Group: Messages Data type: Floating Point
Quick comm. NO Active: YES Data set: DDS
Can be changed: U, T
Min Max Factory setting
0.0 [Nm] 99999.0 [Nm] 99999.0 [Nm]

Table of Contents

Related product manuals