Description: P2832 defines input of NOT 3 element, output is P2833.
Dependency: P2801[11] is active level for the NOT element.
Description: Output of NOT 3 element.
Displays not logic of bit defined in P2832.
Dependency: P2801[11] is active level for the NOT element.
Description: P2834[0], P2834[1], P2834[2], P2834[3] define inputs of D-FlipFlop 1, outputs are P2835, P2836.
Index: [0] = Binector input: Set
[1] = Binector input: D input
[2] = Binector input: Store pulse
[3] = Binector input: Reset
Dependency: P2801[12] is active level for the D-FlipFlop.
p2832 BI: NOT 3 / NOT 3
Access level: 3 P-Group: Technology Data type: Unsigned32
Quick comm. NO Active: NO Data set: -
Can be changed: U, T
Min Max Factory setting
- - 0
r2833.0 BO: NOT 3 / NOT 3
Access level: 3 P-Group: Technology Data type: Unsigned16
Unit: - Data set: -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Output of BO Yes No -
p2834[0...3] BI: D-FF 1 / D-FF 1
Access level: 3 P-Group: Technology Data type: Unsigned32
Quick comm. NO Active: NO Data set: -
Can be changed: U, T
Min Max Factory setting
- - 0
1
p2834
SET (Q=1)
RESET (Q=0)
D
STORE
POWER ON
r2835
r2836
Q
Q
SET RESET D STORE Q Q
10xx10
01xx01
11xxQ
n-1
Q
n-1
001 10
000 01
POWER-ON 0 1
p2800
p2801[12]
Index0
Index1
Index2
Index3