List of Parameters
Parameters
1-55
© Siemens AG 2007 All Rights Reserved
SINAMICS G120 Control Units CU240S, Edition 05/2007
Description: Displays stator resistance calculated in [%] from IGBT ON voltage and current amplitude.
Note:
Description:
Displays stator resistance of motor as [%] of combined stator/cable resistance.
Note:
Description:
Displays (adapted) rotor resistance of the motor equivalent circuit (phase value) in [%].
Notice: Values greater than 25 % tend to produce excessive motor slip.
Check rated motor speed [rpm] value (P0311).
Note:
r0394 CO: Stator resistance IGBT [%] / Stat. res.IGBT
Access level: 4 P-Group: Motor Data type: Floating Point
Unit: [%] Data set: -
% 100 <=>
p03053
p0304
I 3
N
V
N
=
=
Z
N
=
ph
V
ph
I
Rated motor impedance:
r0395 CO: Total stator resistance [%] / Total stat.res
Access level: 3 P-Group: Motor Data type: Floating Point
Unit: [%] Data set: -
% 100 <=>
p03053
p0304
I 3
N
V
N
=
=
Z
N
=
ph
V
ph
I
Rated motor impedance:
r0396 CO: Act. rotor resistance / Act rotor res.
Access level: 3 P-Group: Motor Data type: Floating Point
Unit: [%] Data set: -
% 100 <=>
p03053
p0304
I 3
N
V
N
=
=
Z
N
=
ph
V
ph
I
Rated motor impedance:

Table of Contents