Description: Defines sources of command to start download of parameter set 1 from attached OP.
The first three digits describe the parameter number of the command source, the last digit refers to the bit setting for
that parameter.
Note: Signal of digital input:
0 = No download
1 = Start download parameter set 1 from OP.
Description: Transfers values from drive to External device when none 0.
Parameter P0010 must be set to 30 for this to be possible.
Values: 0: Disabled
1: Start OP Transfer
Note: Parameter is automatically reset to 0 (default) after transfer.
P0010 will be reset to 0 on successful completion.
Description: Transfers values from drive to External device when none 0.
Parameter P0010 must be set to 30 for this to be possible.
Values: 0: Disabled
1: Start OP Transfer
2: Start MMC Transfer
Note: Parameter is automatically reset to 0 (default) after transfer.
P0010 will be reset to 0 on successful completion.
Ensure that enough space exists on the MMC card before transferring data (8kb).
p0801[0...2] BI: Download parameter set 1 / Dwnl.par.set 1
Access level: 3 P-Group: Commands Data type: Unsigned32
Quick comm. NO Active: NO Data set: CDS
Can be changed: T
Min Max Factory setting
- - 0
p0802 Transfer data from EEPROM / Transf.Drive->Ext
CU240E Access level: 3 P-Group: Factory settings Data type: Unsigned16
Quick comm. NO Active: NO Data set: -
Can be changed: -
Min Max Factory setting
0 1 0
p0802 Transfer data from EEPROM / Transf.Drive->Ext
CU240S
CU240S DP
CU240S DP-F
CU240S PN
Access level: 3 P-Group: Factory settings Data type: Unsigned16
Quick comm. NO Active: NO Data set: -
Can be changed: -
Min Max Factory setting
0 2 0