Parameters
List of Parameters
1-42
© Siemens AG 2007 All Rights Reserved
SINAMICS G120 Control Units CU240S, Edition 05/2007
Description: Nominal motor voltage [V] from rating plate.
Following diagram shows a typical rating plate with the locations of the relevant motor data.
Dependency: Changeable only when P0010 = 1 (quick commissioning).
Default value is depending on inverter type and its rating data.
Caution: The input of rating plate data must correspond with the wiring of the motor (star / delta).
This means, if delta wiring is used for the motor, delta rating plate data has to be entered.
p0304[0...2] Rated motor voltage / Rated mot. voltage
Access level: 1 P-Group: Motor Data type: Unsigned16
Quick comm. YES Active: NO Data set: DDS
Can be changed: C
Min Max Factory setting
10 [V] 2000 [V] 400 [V]
P0307
3~Mot
1LA7130-4AA10
EN 60034
Cos ϕ 0.81
1455/min
5.5kW 19.7/11.A
230/400 V ∆/Υ
Cos ϕ 0.82
60 Hz
6.5kW
460 V
10.9 A
1755/min
Υ 440-480
11.1-11.3 A
45kg
∆/Υ 220-240/380-420 V
19.7-20.6/11.4-11.9 A
P0311
P0308
P0305
P0310
95.75%
P0309
50 Hz
No UD 0013509-0090-0031 TICI F 1325 IP 55 IM B3