EasyManua.ls Logo

Siemens Sinamics G120 Series - p2816[0...1] BI: OR 1; OR 1; r2817.0 BO: OR 1; OR 1; p2818[0...1] BI: OR 2; OR 2; r2819.0 BO: OR 2; OR 2

Siemens Sinamics G120 Series
418 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
List of Parameters
Parameters
1-259
© Siemens AG 2007 All Rights Reserved
SINAMICS G120 Control Units CU240S, Edition 05/2007
Description: P2816[0], P2816[1] define inputs of OR 1 element, output is P2817.
Index: [0] = Binector input 0 (BI 0)
[1] = Binector input 1 (BI 1)
Dependency: P2801[3] is active level for the OR element.
Description: Output of OR 1 element.
Displays or logic of bits defined in P2816[0], P2816[1].
Dependency: P2801[3] is active level for the OR element.
Description: P2818[0], P2818[1] define inputs of OR 2 element, output is P2819.
Index: [0] = Binector input 0 (BI 0)
[1] = Binector input 1 (BI 1)
Dependency: P2801[4] is active level for the OR element.
Description: Output of OR 2 element.
Displays or logic of bits defined in P2818[0], P2818[1].
Dependency: P2801[4] is active level for the OR element.
p2816[0...1] BI: OR 1 / OR 1
Access level: 3 P-Group: Technology Data type: Unsigned32
Quick comm. NO Active: NO Data set: -
Can be changed: U, T
Min Max Factory setting
- - 0
A
B
C
p2816
r2817
ABC
000
011
101
111
1
p2800
p2801[3]
Index0
Index1
r2817.0 BO: OR 1 / OR 1
Access level: 3 P-Group: Technology Data type: Unsigned16
Unit: - Data set: -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Output of BO Yes No -
p2818[0...1] BI: OR 2 / OR 2
Access level: 3 P-Group: Technology Data type: Unsigned32
Quick comm. NO Active: NO Data set: -
Can be changed: U, T
Min Max Factory setting
- - 0
r2819.0 BO: OR 2 / OR 2
Access level: 3 P-Group: Technology Data type: Unsigned16
Unit: - Data set: -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Output of BO Yes No -

Table of Contents