Description: PID-MOP mode specification
Note: Defines the operation mode of the motorized potentiometer.
See P2240 (setpoint of PID-MOP).
Description: Inhibits reverse setpoint selection of the PID-MOP.
Values: 0: Reverse direction is allowed
1: Reverse direction inhibited
Note: Setting 0 enables a change of motor direction using the motor potentiometer setpoint (increase/decrease fre-
quency).
The "reversing key" of the OP (e.g. BOP) is not affected by the settings of P2232. Use P1110 to fully prevent
change of motor direction.
Description: Defines source of UP command.
Dependency: To change setpoint:
- Configure a digital input as source
- Use UP / DOWN key on OP (e.g. BOP).
Notice: If this command is enabled by short pulses of less than 1 second, the frequency is changed in steps of 0.2 %
(P0310). When the signal is enabled longer than 1 second the ramp generator accelerates with the rate of P2247.
p2231[0...2] PID-MOP mode / PID-MOP mode.
Access level: 2 P-Group: Technology Data type: Unsigned16
Quick comm. NO Active: YES Data set: DDS
Can be changed: U, T
Min Max Factory setting
- - 0
Bit field: Bit Signal name 1 signal 0 signal FP
00 Setpoint store activ Yes No -
01 No On-state for MOP necessary Yes No -
p2232 Inhibit rev. direct. of PID-MOP / Inhib. PID-MOD rev
Access level: 2 P-Group: Technology Data type: Unsigned16
Quick comm. NO Active: NO Data set: -
Can be changed: T
Min Max Factory setting
0 1 1
p2235[0...2] BI: Enable PID-MOP (UP-cmd) / PID-MOP (UP)
Access level: 3 P-Group: Technology Data type: Unsigned32
Quick comm. NO Active: NO Data set: CDS
Can be changed: T
Min Max Factory setting
- - 19.13