List of Parameters
Parameters
1-225
© Siemens AG 2007 All Rights Reserved
SINAMICS G120 Control Units CU240S, Edition 05/2007
Description: Hysteresis speed (frequency) for overspeed-detection.
For vector control modes (P1300 = 20 - 23), the hysteresis acts above the max. frequency as illustrated in the dia-
gram below.
For v/f control modes (P1300 = 0 - 6), the hysteresis acts below the max. frequency.
Description: Threshold for detecting speed deviation from setpoint.
Note: See diagram in P2164.
p2162[0...2] Hysteresis freq. for overspeed / Overspd. hyst.freq
CU240S
CU240S DP
CU240S DP-F
CU240S PN
Access level: 2 P-Group: Messages Data type: Floating Point
Quick comm. NO Active: YES Data set: DDS
Can be changed: U, T
Min Max Factory setting
0.00 [Hz] 25.00 [Hz] 3.00 [Hz]
0
1
{
Max. frequency
0.00 ... 650.00 [Hz]
p1082.D (50.00)
Overspd. hyst.freq
0.00 ... 650.00 [Hz]
p2162.D (3.00)
f_act > f_max
f_act
f_act > f_max
r2197 Bit06
0T
f_act > f_max
r2197 Bit12
Delay time
0...10000 [ms]
P2152.D (200)
p2163[0...2] Entry freq. for perm. deviation / Entry freq. deviat
Access level: 2 P-Group: Messages Data type: Floating Point
Quick comm. NO Active: YES Data set: DDS
Can be changed: U, T
Min Max Factory setting
0.00 [Hz] 20.00 [Hz] 3.00 [Hz]