EasyManua.ls Logo

Siemens Sinamics G120 Series - p1717[0...2] Integral time current controller; Int.time cur. ctrl; r1718 CO: Output of Isq controller; Outp. Isq ctrl; r1719 CO: Integral output of Isq ctrl.; Int. outp. Isq; r1723 CO: Output of Isd controller; Outp. Isd ctrl

Siemens Sinamics G120 Series
418 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
List of Parameters
Parameters
1-179
© Siemens AG 2007 All Rights Reserved
SINAMICS G120 Control Units CU240S, Edition 05/2007
Description: Enters integral time of current controller.
Description: Displays actual output of Isq current (torque current) controller (PI controller).
It contains the proportional and integral part of the PI controller.
Description: Displays integral output of Isq current (torque current) controller (PI controller).
Description: Displays actual output of Isd current (flux current) controller (PI controller).
It contains the proportional and integral part of the PI controller.
Description: Displays integral output of Isd current (flux current) controller (PI controller).
Description: Displays limit of integral output voltage setpoint of Isd current controller.
Description: Displays actual output voltage setpoint of cross channel decoupling.
Description: Sets oscillation damping gain for sensorless vector control at low frequencies. The oscillation damping subtracts
the result of a delayed differential (DT1) from the setpoint frequency.
p1717[0...2] Integral time current controller / Int.time cur. ctrl
Access level: 4 P-Group: Closed-loop control Data type: Floating Point
Quick comm. NO Active: YES Data set: DDS
Can be changed: U, T
Min Max Factory setting
1.0 [ms] 50.0 [ms] 4.1 [ms]
r1718 CO: Output of Isq controller / Outp. Isq ctrl
Access level: 4 P-Group: Closed-loop control Data type: Floating Point
Unit: [V] Data set: -
r1719 CO: Integral output of Isq ctrl. / Int. outp. Isq
Access level: 4 P-Group: Closed-loop control Data type: Floating Point
Unit: [V] Data set: -
r1723 CO: Output of Isd controller / Outp. Isd ctrl
Access level: 4 P-Group: Closed-loop control Data type: Floating Point
Unit: [V] Data set: -
r1724 CO: Integral output of Isd ctrl. / Int. outp. Isd
Access level: 4 P-Group: Closed-loop control Data type: Floating Point
Unit: [V] Data set: -
r1725 CO: Integral limit of Isd ctrl. / Int. limit Isd
Access level: 4 P-Group: Closed-loop control Data type: Floating Point
Unit: [V] Data set: -
r1728 CO: Decoupling voltage / Decoupl. volt
Access level: 4 P-Group: Closed-loop control Data type: Floating Point
Unit: [V] Data set: -
p1740 Gain for oscillation damping / Oscill. damp. gain
Access level: 3 P-Group: Closed-loop control Data type: Floating Point
Quick comm. NO Active: YES Data set: -
Can be changed: U, T
Min Max Factory setting
0.000 10.000 0.000

Table of Contents

Related product manuals