Connector/Binector (BICO)-Parameters
Parameters
1-311
© Siemens AG 2007 All Rights Reserved
SINAMICS G120 Control Units CU240S, Edition 05/2007
r1024 CO: Act. fixed frequency / Act. FF
r1045 CO: MOP input frequency of the RFG / MOP RFG input
r1050 CO: Act. Output freq. of the MOP / MOP outp.freq.
r1078 CO: Total frequency setpoint / Tot. freq.setp
r1079 CO: Selected frequency setpoint / Sel. freq.setp
r1114 CO: Freq. setp. after dir. ctrl. / Setp<-dir.ctrl.
r1119 CO: Freq. setpoint before RFG / Setp before RFG
r1170 CO: Frequency setpoint after RFG / Setp. after RFG
r1242 CO: Switch-on level of Vdc-max / Vdc-max ON lev
r1246[0...2] CO: Switch-on level kin buffering / KIB ON level
r1315 CO: Total boost voltage / Total boost V
r1337 CO: V/f slip frequency / V/f slip freq.
r1343 CO: Imax controller freq. output / CO:Imax ctrl Foutp
r1344 CO: Imax controller volt. output / CO:Imax ctrl Voutp
r1438 CO: Freq. setpoint to controller / Freq. setp ctl
r1445 CO: Act. filtered frequency / Act. filt freq
r1482 CO: Integral output of n-ctrl. / Int.outp n-ctrl
r1490 CO: Droop frequency / Droop freq.
r1508 CO: Torque setpoint / Torque setp.
r1515 CO: Additional torque setpoint / Add. trq. setp
r1518 CO: Acceleration torque / Accel. torque
p1520[0...2] CO: Upper torque limit / Upper trq. lim
p1521[0...2] CO: Lower torque limit / Lower trq. lim
r1526 CO: Upper torque limitation / Upper trq. lim
r1527 CO: Lower torque limitation / Lower trq. lim
r1536 CO: Max. trq. motoring current / Max trq mot cur
r1537 CO: Max trq regenerative current / Max trq reg cur
r1538 CO: Upper torque limit (total) / Total up TrqLim
r1539 CO: Lower torque limit (total) / Total lw TrqLim
p1570[0...2] CO: Fixed value flux setpoint / Fval flux setp
r1583 CO: Flux setpoint (smoothed) / Smoothed setp.
r1597 CO: Outp. field weak. controller / Outp.weak. ctrl
r1598 CO: Flux setpoint (total) / Total flux setp
r1718 CO: Output of Isq controller / Outp. Isq ctrl
r1719 CO: Integral output of Isq ctrl. / Int. outp. Isq
r1723 CO: Output of Isd controller / Outp. Isd ctrl
r1724 CO: Integral output of Isd ctrl. / Int. outp. Isd
r1725 CO: Integral limit of Isd ctrl. / Int. limit Isd
r1728 CO: Decoupling voltage / Decoupl. volt
r1746 CO: Actual flux variance / Act. flux variance
r1770 CO: Prop. output of n-adaption / Prop outp n-ad
r1771 CO: Int. output of n-adaption / Int. outp n-ad
r1778 CO: Flux angle difference / Flux angle diff
r1782 CO: Output of Rs-adaptation / Output Rs-adaption
r1787 CO: Output of Xm-adaption / Outp. Xm-adaption
r1801[0...1] CO: Pulse frequency / Pulse frequency
r2015[0...7] CO: PZD from USS on RS232 / PZD<-USS
r2018[0...7] CO: PZD from USS on RS485 / PZD<-COM(USS)
r2050[0...7] CO: PZD from Fieldbus / PZD from FB
r2059[0...4] CO: Displays SOL link stats for Sol Master. / Disp SOL stats
r2110[0...3] CO: Warning number / Warning number
r2131 CO: Last fault number code / Last fault code
r2132 CO: First warning number code / First warning code
r2169 CO: Act. filtered frequency / CO:Act. filt. freq
r2224 CO: Act. fixed PID setpoint / Fixed.PID setp