VA Motion Controller Programming Manual
616
output)
instructions executed
First_Done (first
execution is complete)
The output parameter to
TRUE represents the first
instruction execution is
complete, the trigger again,
the parameter is still Ture
BOOL
TRUE or
FALSE
Busy (execution)
This parameter indicates
to TRUE output instruction is
executed
BOOL
TRUE or
FALSE
The Active
(control)
When this parameter is
TRUE indicates output
command under the control
shaft
BOOL
TRUE or
FALSE
Error (error
output bit)
This parameter indicates
the instruction execution error
to TRUE
BOOL
TRUE or
FALSE
The ErrorID
(error code)
Instruction execution
error code error
WORD
Count
Byte length
WORD
0000 ~
FFFF
Data
Output Data
UDINT
0000 ~
FFFF
Function Description
Service data read module, and read by the specified index subindex manner a node address in
the contents of the address Youwenyouda, slow reading speed, reading normally takes a period of
two sync, applied to non-real time data read operation.
Program Example
In the example below when NS_CC_CANopen_SDO_Read instruction execution alone.
1, variables, and procedures
variable name
type of data
The initial value
NS_CC_CANopen_SDO_
Read_1
NS_CC_CANopen_SDO
_Read
AXIF01
USINT
1
Excute
BOOL
FALSE
Index
WORD
16 # 2004
SubIndex
WORD
16 # 0015
AXIF_no_out
WORD
Done
BOOL
Busy
BOOL
Active
BOOL
Error
BOOL