Power Focus allows two different possibilities for Job selection; C201 Job and C202 Job override. To be
able to select a Job at least one of the two parameters has to be set. The parameters are set from
PF Map>Controller>Configuration>Select source. The system remembers the most recently selected source
until the Job is either completed or aborted. After a Job has been started, it is not possible to select a new
Job until Job done or Job aborted.
C202 Job override has a higher priority than C201 Job. If a Job is selected from C202 Job override, then it
always terminates a present Job and is selected instead.
If a Job is selected from the select source in C201 Job, then it is only possible to select a new Job from
the same source before the first tightening in the Job has been done (or after the Job has been ended).
During the Job, it is only possible to select a new Job from the select source in C202 Job override.
If a Job is selected from the select source in C202 Job override, it is only possible to select a new Job from
the same source after the selection and during the Job.
If a Job has been 'overridden' it will be aborted before the new Job is selected.
To be able to select/abort a Job from the PF Graph display, C201 Job or C202 Job override
must be set to “PF keyboard”.
A Cell Job can only be selected or aborted from the Job reference.
To be able to select a Cell Job the Job reference needs to communicate with the Job
clients that form the selected Job. Otherwise the Job reference will not start the Job. All
the Job clients detect communication failure with the Job reference and vice versa. If the
Job reference loses communication with a Job client it will try to re-establish the
communication.