Event codes
386 (428) 9836 3123 01
See also the General safety instructions in this manual, and Product Information for the controller and the
tool.
The events are grouped according to the table below.
Event
code
Group
Description
E001-E099
0
Rundown failures
E100-E199
1
Event related errors
E200-E299
2
User input events
E300-E399
3
Statistical events
E400-E499
4
Communication events
E500-E599
5
Hardware events (tool)
E600-E699
6
Hardware events
E700-E799
7
Hardware events
E800-E899
8
Software events
E900-E999
9
Events MMI
23.1.1 E001-E099 Rundown failures
Event
code
Event name
Description
Procedure
Acknowledge
PF ready
Tool ready
E003
Torque measurement
possibly invalid
The programming is incorrect as
no movement is possible in the
second stage.
Check the programming for the
Pset.
Ensure that there is some movement
in the second stage.

Table of Contents

Other manuals for Atlas Copco Power Focus 3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Atlas Copco Power Focus 3000 and is the answer not in the manual?

Atlas Copco Power Focus 3000 Specifications

General IconGeneral
BrandAtlas Copco
ModelPower Focus 3000
CategoryControl Systems
LanguageEnglish

Related product manuals