Parameter list
9836 3123 01 361 (428)
22.4.2 Configuration
Parameter
number
Parameter name
Description
Default
setup
C200
Pset
Defines what device is to be used when selecting the running Pset.
Available options; Off, Selector, DigIn, Ethernet/Serial, Identifier, Fieldbus,
PF Keyboard, Fieldbus selector, STwrench tag and ST Selector.
Off
C201
Job
Defines what device is to be used when selecting the running Job.
The option is accessible when Job is accessible (RBU type).
Available options; Off, DigIn, Ethernet/Serial, Identifier, Fieldbus and PF
Keyboard
Off
C202
Job override
Defines what device is to be used when selecting the running Job.
This source has a higher priority than C201 Job. The option is accessible when
Job is accessible (RBU type).
Available options; Off, DigIn, Ethernet/Serial, Identifier, Fieldbus and PF
Keyboard
Off
C210
Lock on reject
When this parameter is activated, the tool locks when a NOK tightening has
occurred.
Available options; No, DigIn unlock and Rev ring unlock
To unlock tool use digital input unlock, rev ring unlock, Fieldbus or the
Ethernet/serial protocol.
No
C211
Result of non-
tightenings
Yes/No
If Yes is selected, then a non-tightening event i.e. loosening, batch operation
will generate a result.
If the checkbox is selected, then the non-tightening events; OK loosening,
batch increment or batch decrement generate a result that is stored in the PF
database. This parameter is used for Pset and Multistage. For Job, see J341.
No
C220
Disable loosening at
OK
Yes/No
Used to prevent the operator from loosening a correctly tightened joint.
No
C230
OE positioning type
Reverse/Forward/Reverse Torque Based
Selects type of positioning mode for open end.
Forward
C240
Reset batch at Pset
change
Yes/No
Resets the batch counter when a new Pset is selected.
Yes
C241
Reset batch at Pset
store
Yes/No
Used if batch counter for a Pset is to be stored, and a reset of batch counter is
wanted.
Yes
C242
Decrement batch at
OK loosening
Yes/No/If last tightening OK
If YES, an OK Loosening generates a batch decrement for both OK and NOK
tightening. Set to If last tightening OK to decrement only for OK tightening.
This function only works with a single spindle, NOT with Sync.
No
C243
Batch status at
increment
OK/NOK
Defines if an increment or bypass operation is OK or NOK.
NOK

Table of Contents

Other manuals for Atlas Copco Power Focus 3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Atlas Copco Power Focus 3000 and is the answer not in the manual?

Atlas Copco Power Focus 3000 Specifications

General IconGeneral
BrandAtlas Copco
ModelPower Focus 3000
CategoryControl Systems
LanguageEnglish

Related product manuals