Parameter list
362 (428) 9836 3123 01
Parameter
number
Parameter name
Description
Default
setup
C244
Increase batch at
tightening
OK tightening
OK+NOK tightening
Defines if batch counter shall be increased at OK tightenings or at OK+NOK
tightenings.
OK
C250
Use last Pset
Yes/No
Use last Pset which was selected before Power Focus reboot.
No
C260
Set
Time and date are set by this command.
C270
Events
Opens the window for event log and display options.
22.4.3 Network
Parameter
number
Parameter name
Description
Default
setup
C300
IP address
The IP address is a number for identification in a network.
0.0.0.0
C301
Subnet mask
Specifies the number of IP addresses on the subnet and also the number of PF
that can be placed below a Net reference, if no router is used.
0.0.0.0
C302
Default router
IP address of the router used on the subnet.
0.0.0.0
C310
Channel ID
Identification number of the channel/system to which the programming refers.
Valid values are 0-20. 0 is only used for standalone PF.
0
C311
Channel name
Name of PF. It is possible to use up to 25 characters.
C312
Cell reference IP
Defines the IP address to the Power Focus acting Cell reference.
The Cell reference monitors and collects information from the Cell members
included in the group.
This IP address must be written into each included Cell member.
0.0.0.0
C313
Cell ID number
The Cell ID is a unique number for the Cell reference (a kind of identification
number).
Valid values are 0-1000. Accessible when the Power Focus is a Cell reference.
0
C314
Cell name
A unique name to be able to find the Cell in the network.
It is possible to use up to 25 characters. Accessible when the Power Focus is a
Cell reference.
C315
Net reference IP
Defines the IP address to the Power Focus acting Net reference.
The Net reference monitors and collects information from the Net members
included in the group.
This IP address must be written into each included Net member.
0.0.0.0

Table of Contents

Other manuals for Atlas Copco Power Focus 3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Atlas Copco Power Focus 3000 and is the answer not in the manual?

Atlas Copco Power Focus 3000 Specifications

General IconGeneral
BrandAtlas Copco
ModelPower Focus 3000
CategoryControl Systems
LanguageEnglish

Related product manuals