Event codes
9836 3123 01 387 (428)
23.1.2 E100-E199 Event related errors
Event
code
Event name
Description
Procedure
Acknowledge
PF ready
Tool ready
E102
Rundown prohibited
due to Lock on
Reject
An attempt to make a tightening is
made and tightenings are disabled by
the parameter C210 Lock on reject
because the result was not OK.
Additional parameter information:
First integer parameter: 0=Locked
during tightening, 1=locked during
loosening
Second integer parameter 0=Service
denied, 1=service aborted.
Depending on C210 Lock on reject
configuration, either unlock the tool by
the direction ring or by digital input
Unlock tool or Master unlock tool.
If applicable, reconfigure C210 Lock
on reject.
x
E103
Tool locked by
digital input
One or several of the digital input
functions lock the tool: Tool disable,
Tool tightening disable, Tool loosening
disable.
Additional parameter information:
First integer parameter: 0=Locked
during tightening, 1=locked during
loosening
Second integer parameter 0=Service
denied, 1=service aborted.
Unlock the tool with one of the
following digital input functions:
Tool disable, Tool tightening disable,
Tool loosening disable
Note: Unlock tool or Master unlock
tool will not act as unlock trigger.
x
E107
Rundown prohibited
due to Line control,
batch not enabled
A Job using line control is selected with
parameter Use J330 line control. The
Job does not start until a line control
start signal is received from digital
input function Line control start signal.
Additional parameter information:
First integer parameter: 0=Locked
during tightening, 1=locked during
loosening
Second integer parameter 0=Service
denied, 1=service aborted.
Unlock the tool with one of the
following digital input functions: Line
control start signal, Job abort or
Master unlock tool.
x
E112
Rehit
An attempt to tighten an already
tightened bolt was made.
For information only.
E113
Current limit reached
- Rundown aborted
The current limit has been reached, the
drive is disabled.
Acknowledge the event.
Perform a motor tuning.
Tool>Maintenance>Motor tuning.
x
x
x

Table of Contents

Other manuals for Atlas Copco Power Focus 3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Atlas Copco Power Focus 3000 and is the answer not in the manual?

Atlas Copco Power Focus 3000 Specifications

General IconGeneral
BrandAtlas Copco
ModelPower Focus 3000
CategoryControl Systems
LanguageEnglish

Related product manuals