Connecting devices
32 (428) 9836 3123 01
4.3.2 Tensor STB
For connection of the wireless Tensor STB, ensure the correct tool connection is configured before
starting the pairing procedure. See PF parameters under Tool > Configuration > Connection and Tool >
Configuration > Radio. For instructions on the pairing procedure, see Tensor STB documentation.
Check tool documentation for compatibility between tool, PF
and RBU.
4.3.3 Start-up instruction for open-end tools
The start-up instruction is recommended every time an open-end tool connected PF is started up
(rebooted), or a hot swap of the tool has been made. The advantages of this are a faster tool rotation to the
open-end position, possibility to select C230 OE forward positioning, and automatic generation of alarms.
Note that the operator has the possibility to perform tightenings without completing the start-up
configuration.