11.4.3 Wear indicator
Wear indicator provides a
mechanism to inform tool users
with an event code when it is
time for tool service. It is also
possible to configure a
controller to lock the tool with
parameter T416 Lock tool on
alarm.
The amount of wear before an alarm is issued is set in T433 Alarm factor.
If wear indicator is on it will be reset to initial state after a tool service when a Service
counter reset is performed.
11.4.4 ACTA
The ACTA section contains a tool calibration
session.
The calibration does not work with
Tensor DS tools.
A tool calibration session is started by connecting
the ACTA 4000 to the Power Focus and fitting the
QRTT device to the spindle. One Multistage with
three Psets is used when the calibration is run, one
torque tightening (for torque calibration) and two
different spindle rotations (for loosening and angle
calibration) Psets.