T270 Power save timeout: IRC turns off after this time, if tool is inactive. To reconnect, press trigger once
and Blue LED on tool lights up after approximately 10 seconds.
T271 Start condition: The start condition if using IRC connection for tool. None: Up to 20 tightenings can
be performed if IRC connection is lost (Blue LED off). Connected: IRC connection must be established
(Blue LED on) to run tool. Start request: IRC connection must be established (Blue LED on) and link
time out must not have started.
T272 Link timeout: If the tool loses IRC connection it is considered offline and the connection LED (blue)
on the tool turns off after the link timeout time.
T277 Torque and angle trace: Switch on/off tracing of torque and angle. (Up to 10 traces can be stored in
the tool if connection is lost.)
T290 Primary tool. Note that PF needs to be restarted after changing primary tool setting. Click Store to
save settings.