Event codes
416 (428) 9836 3123 01
battery to Atlas Copco (do not
reuse it!)
23.1.8 E700-E799 Hardware events
This event code is only visible in the event
log and indicates when PF is started.
The backup battery level is low. The
battery should be changed.
Replace the backup battery.
Backup battery
empty or
missing
The backup battery level is very low or the
battery is missing. A new battery should be
inserted as soon as possible.
Replace the backup battery.
Ground fault in
tool circuit
An earth (ground) fail detected, probably a
tool circuit failure
Acknowledge the event.
Rebuild the tool.
An ACTA/QRTT calibration has been
performed. See below for additional
information.
Protective earth
to tool
interrupted
Protective earth between tool and
controller is interrupted.
Acknowledge the event.
Check tool cable, tool and controller.
Tool internal
error - Service
tool
Indicator board overcurrent error. Tool
service needed.
Acknowledge the event.
Service the tool.
The direction ring is not in a defined
position.
Place the direction ring correctly.
There is a mismatch between swivel
lock and tool start source
Wrong gear box is mounted on the tool
Mount the correct gearbox.