Parameter list
9836 3123 01 353 (428)
Parameter
number
Parameter name
Description
Default
setup
P552
PVT range LCL
The lower control limit for range. Calculated automatically or entered
manually.
This function is only available if P220 PVT monitoring is selected.
0 Nm
P553
PVT range UCL
The upper control limit for range. Calculated automatically or entered
manually.
This function is only available if P220 PVT monitoring is selected.
9999 Nm
P554
PVT X-bar-bar
The desired value for calculated mean values for groups of tightenings.
This function is only available if P220 PVT monitoring is selected.
0 Nm
P555
PVT range-bar
The desired value for calculated mean ranges for groups of tightenings.
This function is only available if P220 PVT monitoring is selected.
0 Nm
P560
CM (X-bar) LCL
The lower control limit for mean value.
Calculated automatically or entered manually.
0%
P561
CM (X-bar) UCL
The upper control limit for mean value.
Calculated automatically or entered manually.
9999%
P562
CM R LCL
Defines the low limit for permitted variations in the range calculations.
0%
P563
CM R UCL
Defines the high limit for permitted variations in the range calculations.
9999%
P564
CM (X bar-bar)
Defines the desired CM average for all of the subgroups calculated
automatically or entered manually. (If calculated: In each subgroup the
average tightened CM value is calculated. Then an average is calculated
based on all of the averages.)
0%
P565
CM (R bar)
Defines the desired average of the CM variation for all of the subgroups.
Calculated automatically or entered manually. (In each subgroup the average
tightened CM variation is calculated. Then an average is calculated based on
all of the averages.)
0%
22.2 Multistage
22.2.1 Setup
Parameter
number
Parameter name
Description
M100
View existing
Multistages
To view all existing Multistages.
M101
Create new
Multistage
To create a new Multistage.
M102
Copy Multistage
Used for the copying of an existing Multistage.
M103
Delete Multistage
Used when a Multistage is to be deleted.

Table of Contents

Other manuals for Atlas Copco Power Focus 3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Atlas Copco Power Focus 3000 and is the answer not in the manual?

Atlas Copco Power Focus 3000 Specifications

General IconGeneral
BrandAtlas Copco
ModelPower Focus 3000
CategoryControl Systems
LanguageEnglish

Related product manuals