Parameter list
352 (428) 9836 3123 01
Parameter
number
Parameter name
Description
Default
setup
P525
Angle range-bar
The desired value for calculated mean ranges for groups of tightenings.
0 deg
P530
Rundown angle X-
bar LCL
The lower control limit for mean value.
Calculated automatically or entered manually.
This function is only available if parameter P104 Rundown angle is selected.
0 deg
P531
Rundown angle X-
bar UCL
The upper control limit for mean value.
Calculated automatically or entered manually.
9999 deg
P532
Rundown angle
range LCL
The lower control limit for range.
Calculated automatically or entered manually.
This function is only available if parameter P104 Rundown angle is selected.
0 deg
P533
Rundown angle
range UCL
The upper control limit for range.
Calculated automatically or entered manually.
This function is only available if parameter P104 Rundown angle is selected.
9999 deg
P534
Rundown angle X-
bar-bar
The desired mean value for calculated mean values for groups of tightenings.
This function is only available if parameter P104 Rundown angle is selected.
0 deg
P535
Rundown angle
range-bar
The desired mean value for calculated mean ranges for groups of tightenings.
This function is only available if parameter P104 Rundown angle is selected.
0 deg
P540
Selftap X-bar LCL
The lower control limit for mean value.
Calculated automatically or entered manually.
This function is only available if parameter P210 Selftap is selected.
0 Nm
P541
Selftap X-bar UCL
The upper control limit for mean value.
Calculated automatically or entered manually.
This function is only available if parameter P210 Selftap is selected.
9999 Nm
P542
Selftap range LCL
The lower control limit for range.
Calculated automatically or entered manually.
This function is only available if parameter P210 Selftap is selected.
0 Nm
P543
Selftap range UCL
The upper control limit for range.
Calculated automatically or entered manually.
This function is only available if parameter P210 Selftap is selected.
9999 Nm
P544
Selftap X-bar-bar
The desired value for calculated mean values for groups of tightenings.
This function is only available if parameter P210 Selftap is selected.
0 Nm
P545
Selftap range-bar
The desired value for calculated mean ranges for groups of tightenings.
This function is only available if parameter P210 Selftap is selected.
0 Nm
P550
PVT X-bar LCL
The lower control limit for mean value. Calculated automatically or entered
manually.
This function is only available if P220 PVT monitoring is selected.
0 Nm
P551
PVT X-bar UCL
The upper control limit for mean value. Calculated automatically or entered
manually.
This function is only available if P220 PVT monitoring is selected.
9999 Nm

Table of Contents

Other manuals for Atlas Copco Power Focus 3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Atlas Copco Power Focus 3000 and is the answer not in the manual?

Atlas Copco Power Focus 3000 Specifications

General IconGeneral
BrandAtlas Copco
ModelPower Focus 3000
CategoryControl Systems
LanguageEnglish

Related product manuals