Parameter list
9836 3123 01 351 (428)
The result must be less than or equal to this value in order for it to be
included in the statistical calculations.
Defines the subgroup size for statistical diagrams and control limits. If this
parameter is changed, the results will be recalculated.
Group size can be set between 2 and 20.
Power Focus can automatically calculate statistical control limits. In order for
these limits to be reasonable, they must be performed on a greater number of
tightenings. This parameter is used to set the number of subgroups used for
these calculations.
Defines which subgroups that will be used in the statistical calculations. If the
frequency is 4 then only every fifth subgroup will be used.
The latest number of values (1 - 100) that is used in the statistical
calculations.
With this parameter it is possible to switch on or off the torque SPC alarm
function.
With this parameter it is possible to switch on or off the angle SPC alarm
function.
With this parameter it is possible to switch on or off the current SPC
monitoring alarm function.
The lower control limit for mean value.
Calculated automatically or entered manually.
The upper control limit for mean value.
Calculated automatically or entered manually.
The lower control limit for range.
Calculated automatically or entered manually.
The upper control limit for range.
Calculated automatically or entered manually.
The desired mean value for calculated mean values for groups of tightenings.
The desired mean value for calculated mean ranges for groups of tightenings.
The lower control limit for mean value.
Calculated automatically or entered manually.
The upper control limit for mean value.
Calculated automatically or entered manually.
The lower control limit for range.
Calculated automatically or entered manually.
The upper control limit for range.
Calculated automatically or entered manually.
The desired value for calculated mean values for groups of tightenings.