Statistic
276 (428) 9836 3123 01
Sub-group
results
Description
x
Mean value for the latest completed subgroup
σ
Sigma for the latest completed subgroup
Other definitions
Description
R
Mean of subgroup range (number of subgroups)
X
Mean of subgroup mean (number of subgroups)
In order to rapidly detect changes in the process, Power Focus is equipped with a number of statistical
alarm limits based on the
x
and R calculations for torque and angle.
Statistical Process Control (SPC) functions are used on torque and angle.
All calculations are performed on the Pset that the tool is currently running with.
If any of the following criteria are true, then the stat alarm is lit and a relay (if used) is activated. The tool
may still run even if an alarm is issued. The alarm is only a warning. The alarm signals remain active until
the process falls within all limits again or the result memory is cleared. This means that the alarm does not
switch off during tightening.
19.1 Statistic alarm
x
> UCL
x
< LCL
R > UCL
R < LCL
Cp < 2.0
Cpk < 1.33
SPC
x
and R compared with LCL / UCL alarms cannot function until the LCL and UCL have been
programmed.

Table of Contents

Other manuals for Atlas Copco Power Focus 3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Atlas Copco Power Focus 3000 and is the answer not in the manual?

Atlas Copco Power Focus 3000 Specifications

General IconGeneral
BrandAtlas Copco
ModelPower Focus 3000
CategoryControl Systems
LanguageEnglish

Related product manuals