Statistic
278 (428) 9836 3123 01
19.5 Calculation formulas
When a stat display is requested, the whole memory is calculated. This is also done when shifting Pset.
Power Focus controls the lowest and highest values. If some of these drop out from memory once it is full
(first in – first out), the entire memory is recalculated.
The formula for group range is calculated after each completed subgroup.
The formulas for the statistic parameters used by Power Focus:
= value
n = number of tightenings
Min = minimum value from all the tightenings in the Power Focus memory
Max = maximum value from all the tightenings in the Power Focus memory
minl = minimum acceptable value
maxl = maximum acceptable value
2
1
2
1
1
1
xnX
n
n
i
i
n
s
*3
,
*3
min
MinlXXMaxl
CPK
Tightenings