PF user interface
52 (428) 9836 3123 01
5.2.4 Keypad
Navigates through menus on the display and increases numbers.
Navigates through menus on the display and decreases numbers.
Press the Autoset key to enter Autoset programming mode.
Aset/Ft alternates in the display and the Autoset LED comes on.
Press Enter. Change the P113 Final target value (if required) by
pressing the +/- keys.
Press Enter to select the P113 Final target. Aset is shown in the
display.
Perform a number of tightenings. When Autoset is ready, the
selected Pset number is displayed and the Autoset LED goes out.
To abort Autoset press the Autoset key (exit and no save).
Pressing the Question mark key displays the following
information:
RBU License level: rbu toggle with RBU type. Au = Gold,
Ag = Silver and Br = Bronze.Software version: rEL followed by
version number rolls on the display from right to left.
Tool model name: type toggles with the tool model
name.Current Pset: Pset toggles with the current Pset ID, e.g.
P1.
Current Job: Job toggles with the current Job ID, e.g. J3.
The Enter key is used to execute selected functions and for event
acknowledgement.
Press F (Function key) to display functions. To display function F1 press F once, to display function F2 press F
twice etc. Press Enter to access and edit a function. When finished, press F repeatedly to display result mode
again (or else it takes 30 seconds for the screen to update automatically).
Note: The functionality is dependent on the RBU version.
F1
Setting Final
Target value
F1/Ft alternates in the display. If no Pset is selected F1/---- is displayed.
Press Enter to select a new P113 Final target value. Change the value by pressing the +/- keys.
Press Enter to save and exit. Press F to exit (no save).
F2
Setting
Torque Tune
Factor
F2/tunE alternates in the display if the selected P100 Control strategy is equal to DS control. Otherwise F2/---- is
displayed.
Press Enter to access the torque tune factor. Change the value by pressing the +/– keys (range 80% - 220%,
default value 100%).
Press Enter to save and exit. Press F to exit (no save).