Event codes
9836 3123 01 409 (428)
Event
code
Event name
Description
Procedure
Acknowledge
PF ready
Tool ready
E481
Cell member
registration failed
The Cell member registration failed
because one Cell member is already
registered with the same channel ID.
Acknowledge the event.
In the cell member, open PF Map >
Controller > Network > Cell and
change parameter C310 Channel ID to
be within 1 and 20 and unique within
the cell.
x
x
x
E482
SW version not
compatible with
cell
The application code version differs from
the cell reference. To be able to run the
cell functionality, ensure that all members
in the cell use the same release as the cell
reference.
In the cell members, open PF Map >
Controller > Information and check
C101 Application code version.
Ensure that all cell members have the
same SW version.
E490
Cell ID not valid
The Cell ID configured is not within the
limits permitted. The Cell ID must be
configured between 1 and 999.
Acknowledge the event.
Open PF Map > Controller >
Network > Cell and set C313 Cell ID
to a correct number unique within the
network.
x
x
x
E491
Net member
registration failed
The Net member registration failed
because one Net member is already
registered with the same Cell ID.
Acknowledge the event.
In the Net member, open PF Map >
Controller > Network > Cell and set
C313 Cell ID to a correct number
unique within the network.
x
x
x
E492
SW version not
compatible with
net cell
The application code version differs from
the net reference. To be able to run the net
cell functionality, ensure that all cell
references in the net use the same release
as the net reference.
In the cell members, open PF Map >
Controller > Information and check
C101 Application code version.
Ensure that all cell members have the
same SW version.
23.1.6 E500-E599 Hardware events (tools)
Event
code
Event name
Description
Procedure
Acknowledge
PF ready
Tool ready
E500
New tool
connected
A new tool has been connected to the drive