Event codes
398 (428) 9836 3123 01
23.1.3 E200-E299 User input events
An attempt was made to perform a
tightening with the wrong Pset number.
Additional parameter information:
First integer parameter: 0=Locked during
tightening, 1=locked during loosening
Second integer parameter 0=Service
denied, 1=service aborted.
Check parameter C200 Pset and select
a Pset from the correct source.
Attempt to select Pset from a source not
specified for parameter C200 Pset.
Check parameter C200 Pset and select
a Pset from the correct source.
Not ok to select
new Pset
It is not allowed to select new Pset when
the already selected Pset is auto selected
by Job.
Proceed in the Job order until the Job
is finished.
To select a new Job or Pset;
Select C202 Job override, select new
Job, or select Job off.
Pset configuration
updated
The configuration of the Pset has been
changed.
Identifier source
disabled
An Identifier source is disabled. All
Identifiers sent by a disabled source are
discarded.
Switch back to Automatic Mode to
enable the Identifier source.
Wrong identifier
input source
Wrong input source for an identifier
string.
Open Identifier>Type setup and
check that the input source is correct.
Scan the identifier string.
Event displayed every time a Pset or
Multistage is stored or restored.
Additional parameter information:
First integer parameter: Pset or Multistage
number
Second integer parameter 0=Pset,
1=Multistage
An attempt to start a Job containing a Pset
not present in PF has been performed.
Choose correct Job or reprogram the
Job.
Displayed if fastener (screw or nut)
breaks during yield control.
Ensure that more than one comparison
is obtained before yield is reached.
In ToolsTalk, open the trace monitor
and analyze the tightening.
Change the applicable parameter.
Too few samples
for yield control
Too few samples for mean torque
calculation in yield algorithm.
Increase parameter P262 Window
angle or reduce speed during yield
control.