Event codes
9836 3123 01 399 (428)
This event code is displayed when an
attempt is made to tighten with a final
target out of range (larger than tool max
torque or 9999).
Additional parameter information:
First parameter: Pset number
Second parameter: Parameter number
with an incorrect value
Third parameter: Parameter in second
integer is dependent on this parameter
Fourth parameter: Parameter in second
integer violates this limit.
Change the value for “Final Target” to
a value within tool limits.
Store and try again.
Start final angle
range error
This event code is displayed when an
attempt is made to tighten with a P120
Start final angle out of range.
First parameter: Pset number
Second parameter: Parameter number
with an incorrect value
Third parameter: Parameter in second
integer is dependent on this parameter
Fourth parameter: Parameter in second
integer violates this limit.
Change the value for P120 Start Final
Angle to a value within tool limits.
Store and try again.
Incompatible
system
configuration
Some configurations are not compatible.
Some combinations of devices, tools and
accessories can not be configured.
Usually this is an operator error.
Check configuration in PF.
Configuration set
inconsistent
This event code is displayed if one device
on the I/O bus has the correct ID but
incorrect type specified (for example a
Selector is connected and an RE-Alarm is
configured).
Additional parameter information:
First integer parameter: Number of I/O
device with configuration problems.
Second integer parameter 2=I/O-expander
or Operator panel, 3=RE-alarm, 5=Four-
position socket selector, 6=Eight-position
socket selector.
Acknowledge the event.
Ensure that the ID and the type of I/O
device are the same.