Digital I/O and fieldbus items
314 (428) 9836 3123 01
Name
Description
Fieldbus items
Duration
Tensor ST/SL
String
length
Value
Set signal
/ Reset signal
Time
To next
tightening
Tracking
Blue LED
Sound (time
duration for all)
Illuminator
TLS ST Tag LED
Lifted
socket
number
Indicates which
socket is lifted.
16 bits
OA
Byte 0=Device
ID
Byte 1=lifted
socket number, if
255=more than
one socket lifted
Socket lifted /
socket back to
position
Line
control
alerted 1
Indicates Line
control alert 1
received by Power
Focus.
1 bit
0 = Not used
1 = Line control
alerted 1
Line control alerted
1 / Start new
tightening
X
X
X
X
X
X
Line
control
alerted 2
Indicates Line
control alert 2
received by Power
Focus.
1 bit
0 = Not used
1 = Line control
alerted 2
Line control alerted
2 / Start new
tightening
X
X
X
X
X
X
Line
control
done
Indicates Job with
line control finished
before line control
alert2 input.
1 bit
0 = Not used
1 = Line control
done
Line control done /
Start new tightening
X
X
X
X
X
Line
control
start ack
Indicates that
Power Focus
received Line
control start.
1 bit
0 = Line control
start reset
1 = Line control
start
Line control start
bit set / Line control
start bit reset
X
X
X
X
Line
control
started
Indicates line
control start set in
Power Focus.
Activate with J330
set to Yes.
1 bit
0 = Not used
1 = Line control
start
Line control started
/ Start new
tightening
X
X
X
X
X
Lock at
batch done
Indicate tool locked
at batch done which
is activated by P152
1 bit
0 = Not used
1 = Tool locked
Lock at batch done
/ Unlock tool
X
X
X
X
Logic relay
1-10
The result of a logic configuration with the corresponding number.
(PF4000 only.)
X
X
X
X
Loosening
disabled
Loosening function currently disabled.
X
X
X
X
Low
Any result is below any of the programmed min limits.
X
X
X
X
X
Low angle
Angle result is lower than min angle limit.
X
X
X
X
X
Low
current
Current status is low.
X
X
X
X
X

Table of Contents

Other manuals for Atlas Copco Power Focus 3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Atlas Copco Power Focus 3000 and is the answer not in the manual?

Atlas Copco Power Focus 3000 Specifications

General IconGeneral
BrandAtlas Copco
ModelPower Focus 3000
CategoryControl Systems
LanguageEnglish

Related product manuals