Digital I/O and fieldbus items
9836 3123 01 333 (428)
Function button
(optional)
00….0001 = Job
1
00….1000 = Job
8
Gets off Job mode and unlocks
tool.
Job select input when selecting Job from digital input.
Selects a Job. Job select source
must be set to Fieldbus. Job 0 =
no Job selected.
2 – 8 bits in
the same
byte.
BF
0000 0001 = Job
1
0001 0000 = Job
16
00….0001 = Job
1
00….1000 = Job
8
Sends to PF to check if fieldbus
communication alive.
2 – 8 bits in
the same
byte
BF
00000000 = 0
11111111 = 255
Keep alive
changed
/no signal
Input for a position breaker.
Gives alarm if a Job with line
control is not finished.
0 = Not Used
1 = Line control
alert 1
Line control
alert 1
/no signal
Input for a position breaker.
Gives alarm if a Job with line
control is not finished.
0 = Not Used
1 = Line control
alert 2
Line control
alert 2
/no signal
Input signal to start the line
control function.
Activate with J330 set to Yes.
0 = Not Used
1 = Line control
Line control
start set
/Line control
start reset
DigIn not connected to any function but used by the Logic Operator function.
(PF4000 only)
Unlocks all locks which are
regarded as event controlled.
0 = Not used
1 = Master
Unlock
Master unlock
tool
/no signal
Open protocol
commands disable
When activated all the commands received by the Power Focus via Open Protocol
are rejected.