Parameter list
9836 3123 01 355 (428)
Parameter
number
Parameter name
Description
Default
setup
M220
Min valid stat tq
limit
>=Cycle start, < Max valid stat tq limit
The result must be greater than or equal to this value to be included in the
statistical calculations.
Not accessible when a DS strategy or reverse is selected (see P100 Control
strategy).
Results are only stored in the Multistage, not in the
individual Pset.
P110 Cycle
start
M221
Max valid stat tq
limit
>Min valid stat tq limit, <=tool max torque
The result must be less than or equal to this value to be included in the
statistical calculations.
Not accessible when a DS strategy or reverse is selected (see P100 Control
strategy).
Results are only stored in the Multistage, not in the
individual Pset.
T102 Tool
max torque
M222
Subgroup size
2 - 20
Defines the size of the subgroup that forms the basis for the statistical
calculations. If this parameter is changed, all statistics have to be recalculated
or deleted.
Not accessible when a DS strategy or reverse is selected (see P100 Control
strategy).
Results are only stored in the Multistage, not in the
individual Pset.
4
M223
No. of subgroups
1 - 7500
Power Focus calculates control limits on request. For these limits to be
relevant they must be based on a large number of data, at least 100. This
parameter defines the number of subgroups to be used in the statistical
calculations. If this parameter is changed, all the results have to be
recalculated.
Not accessible when a DS strategy or reverse is selected (see P100 Control
strategy).
10
M224
Subgroup frequency
1 – 7500
This parameter indicates the number of subgroups that are disregarded
between every stored subgroup.
Not accessible when a DS strategy or reverse is selected (see P100 Control
strategy).
1
M225
Latest n values
1 – 100
The number of tightening values which are included in the latest statistical
calculations. Not accessible when a DS strategy or reverse is selected (see
P100 Control strategy).
30
M226
SPC alarm tq
This parameter switches the torque SPC alarm function on or off.
Not accessible when a DS strategy or reverse is selected (see P100 Control
strategy).
Off

Table of Contents

Other manuals for Atlas Copco Power Focus 3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Atlas Copco Power Focus 3000 and is the answer not in the manual?

Atlas Copco Power Focus 3000 Specifications

General IconGeneral
BrandAtlas Copco
ModelPower Focus 3000
CategoryControl Systems
LanguageEnglish

Related product manuals