Event codes
9836 3123 01 411 (428)
Measured values from the tool motortuning
process indicates that the tool is not
running optimally. The tool may run
warmer than normal. Values for supporting
this decision are entered in sub information
arguments 1 to 4.
(This event is default off).
The accuracy of the tool is not
influenced by this problem. However,
if the performance of the tool is
considered to be a problem, send it to
motor service.
Tool type not
supported by
RBU
The tool type is not supported by the RBU.
Acknowledge the event.
Check which RBU-level the tool
requires.
Replace the RBU.
Tool-Power
Focus 3000 size
mismatch
Mismatch between the tool and PF 3000
controller (for example S4/S7 tool
connected to a S9 controller).
Acknowledge the event.
Replace the PF3000 with the correct
PF3000 or a PF4000, to match the
tool.
Tool revision not
supported by this
drive SW
The tool is not supported by the drive
(drive version too old)
Tool EEPROM
corrupt - service
tool
Checksum indicates that tool memory is
corrupt. Tool must be serviced.
Acknowledge the event.
Reprogram the tool and restore the
memory, using Tools Talk service.
Motortune
parameters
invalid -
Motortune
Checksum indicates that the motor tuning
or the open-end tuning table is corrupt.
Additional parameter information:
First integer parameter indicates at which
stage the tool is locked: 0= tightening, 1=
loosening, 2=positioning, 3=motor tuning,
4=open-end tuning, 5=tracking
Second integer parameter 0=Service
denied, 1=service aborted.
Acknowledge the event.
Open Tool>Maintenance and do a
motor tuning or an open-end tuning.
Tool max torque invalid, service tool.
Acknowledge the event.
Set parameter T102 to an appropriate
value.
For S/DS/ETX tools: use TTPF or
Graph.
Other tools: use TTS.