Event codes
414 (428) 9836 3123 01
Condition
change not
reflected in tool,
wireless tool
inaccessible
A condition change in the controller (Pset
selection, Job selection, Job aborted etc.)
could not be reflected in the tool. The tool
was currently inaccessible.
Re-establish connection.
The condition change is now
automatically transferred to the tool.
Tool battery voltage is low.
Replace the tool battery.
Place the discharged battery in the
battery charger.
Tool battery empty. Tool locked.
Replace the battery.
The tool is unlocked automatically.
Tool software
version
mismatch
The implemented protocol version in
Power Focus for connected tool differs
from the protocol version in tool.
Additional parameter information:
First parameter is Power Focus protocol
version. Second parameter is tool protocol
version.
Upgrade the software in tool or PF to
match each other.
An IRC paring sequence has been
successfully completed.
An RBU error was detected by the tool
software.
Check that the RBU is correctly
mounted, otherwise service tool.
Tool locked, do
Store standalone
Tool locked since no Pset has been actively
stored in the tool.
Do Store Standalone or deselect
Standalone, parameter T470 Use
Standalone.
Condition
change not
reflected in tool,
wireless tool
stand alone
A condition change in the controller (Pset
selection, Job selection, Job aborted …)
could not be reflected in the tool. The tool
was currently stand alone
Make changes in the stand alone
interface instead if the change is meant
to apply.
IRC
configuration
mismatch
Not possible to establish radio connection
with wireless tool
Check if tool is in correct operation
mode (Ad-hoc and not Infrastructure
mode);
Also check the PF IRC settings.
Reboot of
wireless tool
needed for
changes to take
effect
Reboot of wireless tool needed for changes
to take effect
Acknowledge the event on the PF and
power cycle the wireless tool.
Locked while
updating
Pset/Job in tool
The controller has locked the tool while
updating the Pset/Job in the (for instance
wireless) tool.