Event codes
9836 3123 01 419 (428)
Event
code
Event name
Description
Procedure
Acknowledge
PF ready
Tool ready
E841
SW function
Not Available
for this tool type
The software function is not available for
this tool type.
Change to the correct tool type.
E851
Connection with
Tools Net server
lost
The connection with the Tools Net server
is lost and the Power Focus is trying to
reconnect. The Tools Net server might be
down or it might be an Ethernet cable
problem.
Check the network configuration and
in particular the ToolsNet IP address,
Subnet mask and Default router.
Check if the ToolsNet server is down.
Check that the Ethernet cables are OK.
Check that the routers and switches are
correctly connected and without
damage.
E856
Router
unreachable
The router in the configuration setting
could not be reached. Check the network
configuration and in particularly the subnet
mask and the default router.
Check the network configuration and
in particular the Subnet mask and the
Default router.
Ping the router to see if it is alive.
Check the Ethernet cable.
E857
Reboot needed
before changes
take effect
The configuration changes will not take
effect until after a system reboot.
Acknowledge the event.
Reboot PF.
If the event reappears, the PF is faulty.
Contact the Atlas Copco service
representative.
x
E858
IP address
already in use
The IP address of this PF is already in use
by another system.
Acknowledge the event.
Change the IP-address in PF.
x
E859
IP address
collision
Another system attempts to use the same
IP address as this PF.
Check the network settings.
E860
Memory
allocation error
Configuration changes has not taken effect
Acknowledge the event and reboot
x
E861
Session handler
internal error
Configuration changes has not taken effect
Acknowledge the event and reboot
x
E862
Ethernet
overload Error
The Ethernet driver of the PF is
temporarily switched off due to an
overloaded network.
Check the network.
E863
IP Port already
in use
An attempt was made to bind a TCP or
UDP socket to a port already in use. For
instance, a user protocol might be using
the same port as ToolsTalk PF.
Acknowledge the event.
Check all network settings.
x

Table of Contents

Other manuals for Atlas Copco Power Focus 3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Atlas Copco Power Focus 3000 and is the answer not in the manual?

Atlas Copco Power Focus 3000 Specifications

General IconGeneral
BrandAtlas Copco
ModelPower Focus 3000
CategoryControl Systems
LanguageEnglish

Related product manuals