Section 7. Installation
CRBasic Program Structure
'Declarations
'Define Constants
Const RevDiff = 1
Const Del = 0 'default
Const Integ = 250
Const Mult = 1
Const Offset = 0
Declare constants
'Define public variables
Public RefTemp
Public TC(6)
'Define Units
Units RefTemp = degC
Units TC = DegC
Declare public variables,
dimension array, and declare
units.
Declarations
'Define data tables
DataTable(Temp,1,2000)
DataInterval(0,10,min,10)
Average(1,RefTemp,FP2,0)
Average(6,TC(),FP2,0)
EndTable
Define data table
'Begin Program
BeginProg
'Set scan interval
Scan(1,Sec,3,0)
'Measurements
PanelTemp(RefTemp,250)
TCDiff(TC()...Offset)
Measure
'Processing (None in this
'example)
Scan loop
'Call data table
CallTable Temp
Call data table
'Controls (None in this
'example)
'Loop to next scan
NextScan
'End Program
EndProg
124

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Campbell CR1000 and is the answer not in the manual?

Campbell CR1000 Specifications

General IconGeneral
Power Requirements9.6 to 16 VDC
Data Logger Operating SystemCRBasic
Memory4 MB
Analog Inputs16 single-ended or 8 differential
Analog Input Resolution13 bits
Analog Input Range+/-2.5V
Digital I/O8
Pulse Counters2
Communication PortsRS-232
Operating Temperature-25°C to +50°C
Pulse Channels4