Section 8. Operation
Editor Compile, Save and Send (p. 511). See Preserving Data at Program Send (p.
127)
for a more-detailed discussion of preserve / erase data at program send.
8.3.3.3 Manual Data-Table Reset
Data-table memory is selectively reset from
Support software Station Status
(p. 529) command
CR1000KD Keyboard Display: Data | Reset Data Tables
8.3.3.4 Formatting Drives
CPU:, USR:, USB:, and CRD: drives can be formatted individually. Formatting a
drive erases all files on that drive. If the currently running user program is found
on the drive to be formatted, the program will cease running and any SRAM data
associated with the program are erased. Drive formatting is performed through
datalogger support software
(p. 654) Format (p. 515) command.
8.3.4 File Management
As summarized in table File Control Functions (p. 382), files in CR1000 memory
(program, data, CAL, image) can be managed or controlled with datalogger
support software
(p. 95), CR1000 Web API (p. 423), or CoraScript (p. 510). Use of
CoraScript is described in the LoggerNet software manual, which is available at
www.campbellsci.com. More information on file attributes that enhance
datalogger security, see the Security
(p. 92) section.
Table 89. File-Control Functions
File-Control Functions Accessed Through
Sending programs to the CR1000
Program Send
1
, File Control Send
2
, DevConfig
3
, keyboard or
powerup.ini with a Campbell Scientific mass storage device or
memory card
4,5
, web API (p. 423) HTTPPut (Sending a File to a
Datalogger)
Setting program file attributes. See File Attributes (p. 383)
File Control
2
;power-up with Campbell Scientific mass storage
device or memory card
5
, FileManage() instruction
6
, web API
FileControl
Sending an OS to the CR1000. Reset CR1000 settings.
DevConfig
3
Send OS tab; DevConfig
3
File Control tab;
Campbell Scientific mass storage device or memory card
5
Sending an OS to the CR1000. Preserve CR1000 settings.
Send
1
; DevConfig
3
File Control tab; power-up with Campbell
Scientific mass storage device or memory card with default.cr1
file
5
, web API HTTPPut (Sending a File to a Datalogger)
Formatting CR1000 memory drives
File Control
2
, power-up with Campbell Scientific mass storage
device or memory card
5
, web API FileControl
Retrieving programs from the CR1000
Retrieve
7
, File Control
2
, keyboard with Campbell Scientific
mass storage device or memory card
4
, web API NewestFile
Prescribes the disposition (preserve or delete) of old data files
on Campbell Scientific mass storage device or memory card
File Control
2
, power-up with Campbell Scientific mass storage
device or memory card
5
, web API (p. 423) FileControl
382

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Campbell CR1000 and is the answer not in the manual?

Campbell CR1000 Specifications

General IconGeneral
BrandCampbell
ModelCR1000
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals