Appendix B. Status, Settings, and Data Table Information (Status/Settings/DTI)
Beacon()
Settings Editor: Beacon Interval
Alias: Communication Ports Beacon Intervals
Keyboard: Settings (comports)
CRBasic: variable = settings.keyword;
SetSettings()
Governs the rate at which the CR1000 broadcasts
PakBus messages on the associated port to discover
new neighboring nodes. It also governs the default
verification interval if the value of Verify()
(p. 632)
for the associated port is 0.
Table 169. Beacon() Array,
Keywords, and Default
Settings
Array
Element
Number
Port
Keyword
(1)
(2)
(3)
(4)
(5)
(6)
ComRS232
ComME
ComSDC7
ComSDC8
ComSDC10
ComSDC11
(7)
(8)
Com1
Com2
(9)
(10)
Com3
Com4
See table Baudrate(), Beacon(), and Verify() Details
read/write
LONG array
seconds
0
0 to
2147483648
BuffDepth
Keyboard: Status Table ≈ line 42
CRBasic: variable = status.keyword
Shows the current Pipeline Mode
(p. 152) processing
buffer depth, which indicates how far the processing
task is currently behind the measurement task.
read only
LONG
0
Table 170. Status/Settings/DTI: C
Keyword
Alias,
Access,
Description
Read/Write,
DataType,
Units
Default
Value
Normal
Range
CalDiffOffset()
2
Keyboard: Status Table ≈ line 63
CRBasic: variable = status.keyword
Array of 18 integers reporting differential offsets for
each integration / range combination. Updated by
background calibration when required.
read only
INTLONG
mV
near 0
612

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Campbell CR1000 and is the answer not in the manual?

Campbell CR1000 Specifications

General IconGeneral
Power Requirements9.6 to 16 VDC
Data Logger Operating SystemCRBasic
Memory4 MB
Analog Inputs16 single-ended or 8 differential
Analog Input Resolution13 bits
Analog Input Range+/-2.5V
Digital I/O8
Pulse Counters2
Communication PortsRS-232
Operating Temperature-25°C to +50°C
Pulse Channels4