Section 7. Installation
Table 43. SDI-12 Commands for Transparent Mode
Command Name
Command Syntax
1
Response
2
Notes
Break
Continuous
spacing for at least
12 milliseconds
None
Address Query
?! a<CR><LF>
Acknowledge Active
a! a<CR><LF>
Change Address
aAb!
b<CR><LF> (support for this command is required only if the sensor
supports software changeable addresses)
Start Concurrent Measurement
aC! atttnn<CR><LF>
Additional Concurrent
Measurements
aC1! ... aC9!
atttnn<CR><LF>
Additional Concurrent
Measurements and Request CRC
aCC1! ... aCC9!
atttnn<CR><LF>
Send Data aD0! ... aD9! a<values><CR><LF> or a<values><CRC><CR><LF>
Send Identification
aI!
allccccccccmmmmmmvvvxxx...xx<CR><LF>. For example,
013CampbellCS1234003STD.03.01 means address = 0, SDI-12 protocol
version number = 1.3, manufacturer is Campbell Scientific, CS1234 is the
sensor model number (fictitious in this example), 003 is the sensor version
number, STD.03.01 indicates the sensor revision number is .01.
Start Measurement
3
aM! atttn<CR><LF>
Start Measurement and Request CRC
3
aMC! atttn<CR><LF>
Additional Measurements
3
aM1! ... aM9!
atttn<CR><LF>
Additional Measurements and
Request CRC
3
aMC1! ... aMC9!
atttn<CR><LF>
Continuous Measurements aR0! ... aR9! a<values><CR><LF> (formatted like the D commands)
Continuous Measurements and
Request CRC
aRC0! ... aRC9! a<values><CRC><CR><LF> (formatted like the D commands)
Start Verification
3
aV! atttn<CR><LF>
1
If the terminator '!' is not present, the command will not be issued. The CRBasic SDI12Recorder() instruction, however, will still pick up data
resulting from a previously issued C! command.
2
Complete response string can be obtained when using the SDI12Recorder() instruction by declaring the Destination variable as String.
3
This command may result in a service request.
SDI-12 Address Commands
Address and identification commands request metadata about the sensor. Connect
only a single probe when using these commands.
?!
Requests the sensor address. Response is address, a.
Syntax:
?!
269

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Campbell CR1000 and is the answer not in the manual?

Campbell CR1000 Specifications

General IconGeneral
Power Requirements9.6 to 16 VDC
Data Logger Operating SystemCRBasic
Memory4 MB
Analog Inputs16 single-ended or 8 differential
Analog Input Resolution13 bits
Analog Input Range+/-2.5V
Digital I/O8
Pulse Counters2
Communication PortsRS-232
Operating Temperature-25°C to +50°C
Pulse Channels4