EasyManuals Logo
Home>Campbell>Measuring Instruments>CR1000

Campbell CR1000 User Manual

Campbell CR1000
678 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #282 background imageLoading...
Page #282 background image
Section 7. Installation
Table 45. Example Power Usage Profile for a Network of SDI-12 Probes
Time (s) Command
All
Probes
Awake
Time
Out
Expires 1 mA 2 mA 3 mA 4 mA
Total
mA
1
1M!
Yes 120 66 66 66 318
2 120 66 66 66 318
14 120 66 66 66 318
15 Yes 120 66 66 66 318
16
1D0!
Yes 66 66 66 66 264
17 66 66 66 66 264
29 66 66 66 66 264
30 Yes 66 66 66 66 264
31 0.25 0.25 0.25 0.25 1
35 0.25 0.25 0.25 0.25 1
7.9.19 String Operations
String operations are performed using CRBasic string functions, as listed in String
Functions
(p. 574).
7.9.19.1 String Operators
The table String Operators (p. 282) lists and describes available string operators.
String operators are case sensitive.
282

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Campbell CR1000 and is the answer not in the manual?

Campbell CR1000 Specifications

General IconGeneral
BrandCampbell
ModelCR1000
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals