Appendix A. CRBasic Programming Instructions
A.5.9 Specific Sensors
ACPower
Measures ac mains power and power-quality parameters for single-, split-, and
three-phase 'Y' configurations. DO NOT CONNECT AC MAINS POWER
DIRECTLY TO THE CR1000.
Syntax
ACPower(DestAC, ConfigAC, LineFrq, ChanV, VMult, MaxVrms,
ChanI, IMult, MaxIrms, Reps)
DANGER Ac mains power can kill. You are responsible for ensuring
connections to ac mains power conforms to applicable electrical codes. Contact a
Campbell Scientific application engineer for information on available isolation
transformers.
CS110
Measures electric field by means of a CS110 electric-field meter.
Syntax
CS110(Dest, Leakage, Status, Integ, Mult, Offset)
CS110Shutter
Controls the shutter of a CS110 electric-field meter.
Syntax
CS110Shutter(Status, Move)
CS616
Enables and measures a CS616 water content reflectometer.
Syntax
CS616(Dest, Reps, SEChan, Port, MeasPerPort, Mult, Offset)
CS7500
Communicates with the CS7500 open-path CO
2
and H
2
O sensor. The CS7500 is
the same product as the LI-COR LI-7500.
Syntax
CS7500(Dest, Reps, SDMAddress, Command)
CSAT3
Communicates with the CSAT3 three-dimensional sonic anemometer.
Syntax
CSAT3(Dest, Reps, SDMAddress, CSAT3Cmd, CSAT3Opt)
EC100
Communicates with the EC150 Open Path and EC155 Closed Path IR Gas
556