Section 7. Installation
'Measure SDI-12 sensors
SDI12Recorder(Temp_Tmp(1),1,0,cmd(1),1.0,0)
SDI12Recorder(Temp_Tmp(2),1,1,cmd(2),1.0,0)
SDI12Recorder(Temp_Tmp(3),1,2,cmd(3),1.0,0)
SDI12Recorder(Temp_Tmp(4),1,3,cmd(4),1.0,0)
'Control Measurement Event
For X = 1 To 4
If cmd(X) = "C!" Then Retry(X) = Retry(X) + 1
If Retry(X) > 2 Then IndDone(X) = -1
'Test to see if ttt expired. If ttt not expired, load "1e9" into first variable
'then move to next instruction. If ttt expired, issue aDv! command(s).
If ((Temp_Tmp(X) = 2e9) OR (Temp_Tmp(X) = 1e9)) Then
cmd(X) = "C" 'Start sending "C" command.
ElseIf(Temp_Tmp(X) = NAN) Then 'Comms failed or sensor not attached
cmd(X) = "C!" 'Start measurement over
Else 'C!/C command sequence complete
Move(Temp_Meas(X),1,Temp_Tmp(X),1) 'Copy measurements to SDI_Val(10)
cmd(X) = "C!" 'Start next measurement with "C!"
IndDone(X) = -1
EndIf
Next X
'Summarize Measurement Event Success
For X = 1 To 4
GroupDone = GroupDone + IndDone(X)
Next X
'Stop current measurement event, reset controls
If GroupDone = -4 Then
RunSDI12 = False
GroupDone = 0
For X = 1 To 4
IndDone(X) = 0
Retry(X) = 0
Next X
Else
GroupDone = 0
EndIf
EndIf 'End of measurement sequence
NextScan
EndProg
SDI12Recorder() sends any string enclosed in quotation marks in the Command
parameter. If the command string is a non-standard SDI-12 command, any
response is captured into the variable assigned to the Destination parameter, so
long as that variable is declared As String. CRBasic example Use of an SDI-12
Extended Command
(p. 279) shows appropriate code for sending an extended SDI-
12 command and receiving the response. The extended command feature has no
built-in provision for responding with follow-up commands. However, the
program can be coded to parse the response and issue subsequent SDI-12
commands based on a customized evaluation of the response. For more
278

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Campbell CR1000 and is the answer not in the manual?

Campbell CR1000 Specifications

General IconGeneral
Power Requirements9.6 to 16 VDC
Data Logger Operating SystemCRBasic
Memory4 MB
Analog Inputs16 single-ended or 8 differential
Analog Input Resolution13 bits
Analog Input Range+/-2.5V
Digital I/O8
Pulse Counters2
Communication PortsRS-232
Operating Temperature-25°C to +50°C
Pulse Channels4