Section 8. Operation
Example page source output:
<BrowseSymbolsResponse>
..<symbol
name="Status"
uri="dl:Status"
type="6"
is_enabled="true"
is_read_only="false"
can_expand="true"/><symbol
name="MainData"
uri="dl:MainData"
type="6"
is_enabled="true"
is_read_only="false"
can_expand="true"/><symbol
name="BallastTank1"
uri="dl:BallastTank1"
type="6"
is_enabled="true"
is_read_only="false"
can_expand="true"/><symbol
name="BallastTank2"
uri="dl:BallastTank2"
type="6"
is_enabled="true"
is_read_only="false"
can_expand="true"/><symbol
name="BallastTank3"
uri="dl:BallastTank3"
type="6"
is_enabled="true"
is_read_only="false"
can_expand="true"/><symbol
name="BallastTank4"
uri="dl:BallastTank4"
type="6"
is_enabled="true"
is_read_only="false"
can_expand="true"/><symbol
name="BallastLine"
uri="dl:BallastLine"
type="6"
is_enabled="true"
is_read_only="false"
can_expand="true"/><symbol
name="Public"
uri="dl:Public"
type="6"
is_enabled="true"
is_read_only="false"
can_expand="true"/>
</BrowseSymbolsResponse>
JSON Response
When json is entered in the BrowseSymbols format parameter, the response will
be formated as CSIJSON
(p. 90). Following is an example response.
430

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Campbell CR1000 and is the answer not in the manual?

Campbell CR1000 Specifications

General IconGeneral
Power Requirements9.6 to 16 VDC
Data Logger Operating SystemCRBasic
Memory4 MB
Analog Inputs16 single-ended or 8 differential
Analog Input Resolution13 bits
Analog Input Range+/-2.5V
Digital I/O8
Pulse Counters2
Communication PortsRS-232
Operating Temperature-25°C to +50°C
Pulse Channels4

Related product manuals