Section 8. Operation
....},
...."fields": [{
......"name": "Induced_Water",
......"type": "xsd:float",
......"process": "Smp",
......"settable": false}]
},
......"data": [{
......"time": "2012-08-21T22:41:50",
......"no": 104,
......"vals": [66]
},{
......"time": "2012-08-21T22:42:00",
......"no": 105,
......"vals": [66]
},{
......"time": "2012-08-21T22:42:10",
......"no": 106,
......"vals": [66]
},{
......"time": "2012-08-21T22:42:20",
......"no": 107,
......"vals": [66]
},{
......"time": "2012-08-21T22:42:30",
......"no": 108,
......"vals": [66]
}]}
TOA5 Response
When toa5 is entered in the DataQuery format parameter, the response will be
formated as Campbell Scientific TOA5. Following is an example response:
"TOA5","TXSoil","CR1000","No_SN","CR1000.Std.25","TexasRun_1b.CR
2","12645","_1Hr"
"TIMESTAMP","RECORD","ID","_6_inch","One","Two","Three","Temp_F_
Avg","Rain_in_Tot"
"TS","RN","","","","","","",""
"","","Smp","Smp","Smp","Smp","Smp","Avg","Tot"
"2012-05-03 17:00:00",0,0,-0.8949984,-0.95232,-0.8949984,-
0.8637322,2.144136,0.09999999
"2012-05-03 18:00:00",1,0,-0.9106316,-0.9731642,-0.9210536,-
0.8845763,72.56885,0
"2012-05-03 19:00:00",2,0,-0.9210536,-0.9679532,-0.9106316,-
0.8637322,72.297,0
"2012-05-03 20:00:00",3,0,-0.8624293,-0.9145398,-0.8624293,-
0.8311631,72.68445,0
"2012-05-03 21:00:00",4,0,-0.8949984,-0.9471089,-0.9002095,-
0.8585211,72.79237,0
"2012-05-03 22:00:00",5,0,-0.9262648,-0.9731642,-0.9158427,-
0.8793653,72.75194,0
"2012-05-03 23:00:00",6,0,-0.8103188,-0.8624293,-0.8103188,-
0.7686304,72.72644,0
"2012-05-04 00:00:00",7,0,-0.9158427,-0.9627421,-0.9158427,-
0.8689431,72.67271,0
"2012-05-04 01:00:00",8,0,-0.8598238,-0.9015122,-0.8598238,-
0.8129244,72.64571,0
"2012-05-04 02:00:00",9,0,-0.9158427,-0.9575311,-0.9054205,-
0.8689431,72.5931,0
435

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Campbell CR1000 and is the answer not in the manual?

Campbell CR1000 Specifications

General IconGeneral
Power Requirements9.6 to 16 VDC
Data Logger Operating SystemCRBasic
Memory4 MB
Analog Inputs16 single-ended or 8 differential
Analog Input Resolution13 bits
Analog Input Range+/-2.5V
Digital I/O8
Pulse Counters2
Communication PortsRS-232
Operating Temperature-25°C to +50°C
Pulse Channels4