Appendix A. CRBasic Programming Instructions
Syntax
variable = DaylightSaving(DSTSet, DSTnStart, DSTDayStart,
DSTMonthStart, DSTnEnd, DSTDayEnd, DSTMonthEnd, DSTHour)
DaylightSavingUS
Determine if US daylight saving time has begun or ended. Optionally advance or
turn back the CR1000 clock one hour.
Syntax
variable = DaylightSavingUS(DSTSet)
IfTime
Returns a number indicating True (-1) or False (0) based on the CR1000 real-
time clock.
Syntax
If (IfTime(TintoInt, Interval, Units)) Then
-or-
Variable = IfTime(TintoInt, Interval, Units)
PakBusClock
Sets the CR1000clock to the clock of the specified PakBus device.
Syntax
PakBusClock(PakBusAddr)
RealTime
Parses year, month, day, hour, minute, second, micro-second, day of week, and/or
day of year from the CR1000 clock.
Syntax
RealTime(Dest)
SecsSince1990
Returns seconds elapsed since 1990. Data type is LONG. Used with
GetRecord().
Syntax
SecsSince1990(date, option)
TimeIntoInterval
Returns a number indicating True (-1) or False (0) based on the datalogger real-
time clock.
Syntax
Variable = TimeIntoInterval(TintoInt, Interval, Units)
-or-
579

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Campbell CR1000 and is the answer not in the manual?

Campbell CR1000 Specifications

General IconGeneral
Power Requirements9.6 to 16 VDC
Data Logger Operating SystemCRBasic
Memory4 MB
Analog Inputs16 single-ended or 8 differential
Analog Input Resolution13 bits
Analog Input Range+/-2.5V
Digital I/O8
Pulse Counters2
Communication PortsRS-232
Operating Temperature-25°C to +50°C
Pulse Channels4