4/4
2. Replacement and adjustment of parts
26810
26810
Zigzag adjustment
6. Perform the master correction of the exposure center correction.
☞36070
IMPORTANT
• Carry out the master correction of the exposure center correction for each paper magazine A, A2, B, and C.
• Make a test print via Test Print Confirmation with Master Value to check the misalignment of the test print.
If it is within 0.2 mm, no adjustment is required.
NOTE
• After performing Exposure Center Correction (Master), perform Exposure Center Correction (for each Paper Magazine)
if you use other paper magazines.
Test print Tolerance range
Test print 1 (457.0 mm) A − C is within ±0.5 mm
Test print 2 (914.0 mm) A − C is within ±1.0 mm
A
BC
Line A
Line C
G078473
A
Left end of the paper
Center line
Right end of the paper
G068463