15/16
4. Troubleshooting
45900
45900
Error message: F replenishment
No. 05923[F]
Solution remains in the replenishment tank.
Error message release
YES
IMPORTANT
• If the above error message is shown, do not click YES to close it and continue the printing process without performing the
diagnosis below.
After a set number of prints are output,
☞No. 05912[F] Predetermined process amount was exceeded. will be shown,
and then printing cannot be performed.
NOTE
• If printing process is continued after the above error is shown, the time is counted as Replenishment Lack Time and the P1R, P2RA
and P2RB replenishers will not be replenished.
Condition
NOTE
• When Mixing Replenisher is clicked and the (lower) replenishment solution level sensors of P1R, P2RA or P2RB is on, the following
attention message is displayed.
☞No. 00913[F] Mixing Replenisher cannot be started.
Check Point
Condition
• The causes are shown below.
1. The replenishment solution cannot be detected by P1R (Lower) Replenishment Solution Level Sensor/P2RA (Lower)
Replenishment Solution Level Sensor/P2RB (Lower) Replenishment Solution Level Sensor, because the amount of the
replenishment solution decreases.
2. Mixing replenisher is in standby status when starting the mixing replenisher automatically, because the Interlock Switch
(Replenisher Section Door) is opened.
3. When # # # (lower) replenishment solution level sensor detects the replenishment solution while the mixing replenisher is in
standby status.
Suffix number Condition
00001 P1R
00002 P2RA
00004 P2RB
For details of operation specification, see ☞ 57010.
• For the QSS-3701/3702/3703/LP7500/LP7600, about 507 prints whose size is 127 mm × 89 mm can be processed after the error
occurs.
• For the QSS-3704/3705/LP7700/LP7900, about 545 prints whose size is 127 mm × 89 mm can be processed after the error occurs.
The above-mentioned error can be canceled when one of the following conditions are fulfilled.
• Mixing Replenisher is performed without solution in each replenishment tank.
• All the (lower) and (upper) replenishment solution level sensors of each replenishment tank are on.
Countermeasure
1. Perform recovery procedure 3 from the replenishment error. ☞4621
Check the status of # # # (lower) replenishment solution level sensors of each processing solution with